DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-299CLSFY-PT (Call Classifier Port)
10
CLSFY-PT (Call Classifier Port)
The TN744 Call Classifier (CLSFY-BD) circuit pack is a service circuit pack that
enables usage of the Outbound Call Management (OCM) and the Inbound Call
Management (ICM) features. On a G3iV2-386 system, the TN744 also enables
usage of R2-MFC signaling for incoming and outgoing feature operation. There
are eight ports (CLSFY-PTs) on the Call Classifier circuit pack. Each port can
handle call classification, touch-tone reception, or, for G3iV2-386 systems, MFC
tone generation and detection or touch-tone reception.
The CLSFY-PT maintenance feature defines a set of tests to ensure that the Call
Classifier circuit pack ports are capable of detecting tones for call classification,
and detecting and generating necessary tones for correct MFC feature
operation.
1. Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier
designation (e.g., A, B, C, D, or E); SS is the address of the slot in the carrier where the
circuit pack is located (e.g., 01, 02, ..., etc.); and pp is the 2-digit port number (e.g.., 01).
MO Name As It
Appears in
Alarm Log Alarm Level
Initial System
Technician
Command to Run
1
Full Name of MO
CLSFY-PT(a) MAJOR test port PCSSpp sh Call Classifier Port
Maintenance
CLSFY-PT MINOR test port PCSSpp sh Call Classifier Port
Maintenance
CLSFY-PT WARNING release port PCSSpp Call Classifier Port
Maintenance