Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-483DIG-LINE (Digital Line)
10
complete. Crosstalk testing is performed on both the primary information channel
(voice) and the secondary information channel (data) associated with each
digital station port. If this test fails on either channel, the station and the DTDM
are taken out-of-service.
Table 10-130. TEST #9 Digital Line NPE Crosstalk Test
Error
Code
Test
Result Description/ Recommendation
1 ABORT During testing of the primary information channel,
system resources may not have been available. Also,
the port may have been busy during the test.
1. Check the port status. Use the display port
UUCSSpp command to determine the station
extension of the port. Use the status station
command to determine the service state of the port.
If the service state indicates that the port is in use,
then the port is unavailable for this test. You will have
to wait until the port is idle.
2. If the port status is idle, then retry the command a
1-minute intervals a maximum of 5 times.
3. If the test continues to abort, escalate the problem.
2 ABORT During testing of DTDM, system resources may not have
been available. Also, the port may have been busy
during the test.
1. Check if port is being used. If possible, disconnect
by toggling disconnect button on DTDM. Retry
command after 1 minute.
!
WARNING:
This action will drop the call in progress.
2. If the test continues to abort after 5 attempts,
escalate the problem.