Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-685upgrade software
8
Synopsis
Simplex/Duplex
2
upgrade software
Permissions
The following logins may execute this command: system technician, inads, init.
Examples
Simplex/Duplex
upgrade software
Description
Simplex
The command verifies that a software card-mem is present and then, if present,
proceeds to reprogram the flash memory and perform a level-4 restart. During
the restart of the system, the system technician is prompted to replace the
software card-mem with the translation card-mem. Service is provided upon
completion of the system restart. Service down time is between 5 to 12 minutes.
Duplex
The command verifies that a software card-mem is present in the standby SPE,
programs the flash memory, resets the standby SPE, and prompt the system
technician to replace the software card-mem with the translation card-mem as in
the simplex case. An interchange of SPE’s is performed upon completion of a
successful standby upgrade. At the same time, the old active SPE is upgraded
automatically with the new software through similar swapping of card-mems. The
service disruption is between 1 to 4 minutes, which is less disruptive than the
simplex case.
Defaults
None.
2. In this context,
simplex
is equivalent to the
stand reliability option
In this context,
duplex
is equivalent to the high reliability option or
critical reliability option
.