DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1260STBY-SPE (Standby SPE)
10
257 (n) 0
2014
2015
2017
2021
2024
2048
2049
2050
2051
2054
Standby SPE Not Put
Into Standby Mode
MAJOR ON refresh spe-standby
(See note (n).
801 (o) any No response from
Standby SPE after
upgrade
MAJOR ON upgrade software
802 (p) any Checksum on Standby
SPE failed after
upgrade
MAJOR ON upgrade software
803 (q) any No translation
card-mem inserted
after Standby SPE
upgrade
MAJOR OFF upgrade software
804 (r) any Lost communication
with Standby SPE
during reboot following
upgrade
MAJOR ON upgrade software
805 (s) any No software mem-card
inserted in active SPE
MAJOR OFF upgrade software
806 (t) any Checksum on new
Standby SPE failed
MAJOR ON upgrade software
807 (u) any No translation
mem-card inserted in
new Standby SPE
MAJOR OFF
808 (v) any Lost communication
with new Standby SPE
MAJOR ON upgrade software
809 (w) any Failed to perform
SPE-interchange
MAJOR OFF upgrade software
810 (x) any Bad checksum on
software mem-card
MAJOR OFF upgrade software
Table 10-391. Standby SPE Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value