Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-419DAT-LINE (Data Line)
10
Digital Loop Around Test (#171)
The Digital Loop Around Test checks the Data Line’s ability to transmit and
receive data on the TDM Bus. Data is sent through Network Control Data
Channel 3 (data channel port 3) over the TDM Bus, internally looped through the
Data Line back onto the TDM Bus, and received again by Network Control Data
Channel 3.
If data channel 3 is in use or not administered, this test aborts. This test may fail if
Network Control Data Channel 3 is not functioning properly. If there are any
DATA-CHL errors in the Error Log, refer to the DATA-BD (Network Control Circuit
Pack) Maintenance documentation to clear them up first. This test passes
regardless of any customer equipment that may be connected to the port, as
long as the port is not in use by the equipment.
Table 10-117. TEST #36 Audit Update Test
Error
Code
Test
Result Description/ Recommendation
1006 ABORT The test did not run due to an already existing error on this port (Error Type
769).
1. Refer to the procedure for Error Type 769. If Error Type 769 still occurs
on this port, replace the circuit pack.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
7 FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS The hardware port state is consistent with the software state. User-reported
troubles on this port should be investigated using other port tests,
examining the ADU, external wiring, and customer equipment.
Continued on next page