Maintenance Object Repair Procedures
Page 10-692EXP-INTF (Expansion Interface Circuit Pack)
10
12026 ABORT Expansion Interface circuit pack reset successfully. It responded
with an unknown reply to the query for the results of its initialization
tests.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, replace the circuit pack or
transceiver.
1 FAIL The Expansion Interface did not successfully reset.
1. If the Expansion Interface circuit pack is in the EPN, the EPN
Maintenance Board may be holding the Expansion Interface
circuit pack reset. Attempt to rectify this condition by executing
the test maint P long command on the maintenance board in
the same EPN.
2. If Step #1 was not successful in releasing the Expansion
Interface circuit pack, temporarily remove the EPN
maintenance circuit pack.
3. Repeat the reset board PCSS command.
4. If reset continues to fail, replace circuit pack.
5. Insert EPN maintenance circuit pack if it was removed.
2 FAIL The Expansion Interface circuit pack was successfully reset, but it
did not begin running after the reset.
1. If the Expansion Interface circuit pack is in the EPN, temporarily
remove the EPN maintenance circuit pack.
2. Repeat the reset board PCSS command.
3. Re-insert the EPN maintenance circuit pack if it was removed.
Table 10-197. TEST #336 Expansion Interface Reset Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page