DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-685EXP-INTF (Expansion Interface Circuit Pack)
10
2000 ABORT Response to the test request was not received within the allowable
time period.
2100 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2060 ABORT The link on the Packet Bus being used to perform the test has
failed.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, check for problems with the
Packet Control circuit pack (look for PKT-CTL errors).
2500 ABORT An internal operation failed; the test could not be completed.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1 FAIL The test did not detect the test tone through the loop around
connection.
NOTE:
If the circuit pack is a TN570, the packet portion of this test
was not run since the circuit portion failed.
1. Test the Active Tone-Clock on the Port Network that contains
the defective Expansion Interface circuit pack to verify that dial
tone is being supplied.
2. If the Tone-Clock is healthy, issue the test board PCSS long
command on the Expansion Interface circuit pack.
3. If this test continues to fail, replace the Expansion Interface
circuit pack or transceiver. Then, reissue the test board PCSS
long command on the new Expansion Interface circuit pack.
Table 10-195. TEST #242 Expansion Interface Lightwave
Transceiver Loop Around Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page