DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1364TAPE (Tape Unit) [G3iV1.1-286]
10
9023 Write-protected tape. 1. Disable the write-protect switch on the
tape cartridge.
2. Check the power by performing Step 1
of the ‘‘
Tape Maintenance and Repair
Procedures’’ section.
3. If the problem still exists, escalate the
problem.
9024 No tape cartridge in tape
drive.
1. Do the steps below following the
directions in the ‘‘
Tape Maintenance
and Repair Procedures’’ section.
2. Issue the test tape long command.
3. If the test fails, make sure tape is fully
inserted.
4. If the test continues to fail, clean the
tape head and retest.
5. If fail, swap tape and retest.
6. If the test still fails, swap tape unit,
use
original tape
and retest.
7. If the problem still exists, escalate the
problem.
9025 Tape cartridge is worn, and
it is NOT functional.
1. Do the steps below following the
directions in the ‘‘
Tape Maintenance
and Repair Procedures’’ section.
2. Clean the tape head.
3. If still fail, check tape insertion, swap
tape if necessary, and retest.
4. Replace tape unit as a last resort.
5. If the problem still exists, escalate the
problem.
Table 10-415. Table A: Tape Unit Aux Data Table — Continued
Aux Data/
Error Codes Explanation Strategy
Continued on next page