DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-844ISDN-TRK (DS1 ISDN Trunk)
10
PASS The call worked. A test pattern was sent and received properly; the
communications path is OK if the synchronous test call command was
issued. If the test isdn-testcall command was issued, a PASS indicates
that the test call was established. A status isdn-testcall command must be
invoked to query the bit and block error rates to determine if the test call
passed. An in-depth analysis of the DS1 facility including the transmission
facility and any external equipment such as DACs, CSUs, etc., should take
place if the bit and block error rates are not acceptable.
Table 10-237. TEST #258 ISDN TEST Call — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page