DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1358TAPE (Tape Unit) [G3iV1.1-286]
10
23002
to
23005
FAIL Hardware not responding.
1. Follow the instructions provided in the ‘‘
Tape
Maintenance and Repair Procedures’’ section.
23006 FAIL Could not send a test message to MTP.
1. Repeat the same test again.
2. Look for PROCR and MEM-BD errors in the Error
Log. If such errors are present, refer to PROCR
(80286 Processor circuit pack) and MEM-BD
(Memory) Maintenance documentation.
3. If no tests on the Memory circuit pack or Processor
circuit pack fail, escalate the problem.
23007 FAIL Operation timed out.
1. Do the steps below following the directions in the
‘‘
Tape Maintenance and Repair Procedures’’
section.
2. Issue the test tape long command.
3. If the test fails, make sure tape is fully inserted.
4. If the test continues to fail, clean the tape head and
retest.
5. If fail, swap tape and retest.
6. If the test still fails, swap tape unit,
use original tape
and retest.
7. If the problem still exists, escalate the problem.
23008 FAIL MTP indicates a test failure.
1. Follow the instructions provided in the ‘‘
Tape
Maintenance and Repair Procedures’’ section.
2. If the problem still exists, escalate the problem.
23009
to
23017
FAIL Hardware problem. Problem accessing test Memory
locations #1, #2, and #3.
1. Follow the procedures provided in the ‘‘
Tape
Maintenance and Repair Procedures’’ section.
2. If the problem still exists, escalate the problem.