DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-233list testcalls
8
Description
The list testcalls command is used to examine ATMS trunk measurements. The
ATMS is a feature which allows the voice and data trunk facilities to be measured
for satisfactory transmission performance. The performance of the trunks are
evaluated according to measurements produced by a series of analog tests and
are compared against user defined threshold values. The list testcalls command
is a reporting mechanism designed to display the measurements produced by
these tests.
The measurement report contains data on trunk signal loss, noise, singing return
loss, and echo return loss. The purpose of the report is to provide measurement
data to help determine the quality of trunk lines.
The measurements are produced by a set of analog trunk tests. The tests are
initiated by a maintenance demand test or by a set of scheduled tests. The
largest portion of these measurements are generated through scheduled testing
during system quiet hours (hours where the traffic volume is low). Each trunk test
performed by the system stores the results in a database. The trunk
measurements in this database reflect the state of each trunk at the time of its
last test.
Defaults
None.
Parameters
detail This option specifies that a detailed measurement report is displayed
(See example of the screen).
summary This option specifies that a summary measurement report is displayed
(See example of the screen).
grp group
number
This option is used to specify that measurements for a specific trunk
group are displayed. When used with the "to-grp" option, this option is
the starting trunk group in a range of user specified trunk groups.
to-grp group
number
This option is used to specify that measurements for all trunk groups
from 1 to the specified "to-grp" trunk group are displayed. When used
with the "grp" option, this option is the ending trunk group in a range of
user specified trunk groups.
mem
member
number
This option is used to specify that measurements for a specific trunk
group member are displayed. When used with the "to-mem" option,
this option is the starting trunk group member in a range of user
specified trunk group members.