DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1620UDS1-BD (UDS1 Interface Circuit Pack)
10
2 FAIL The test failed because it was not set up properly. The
UDS1 pack could not successfully put the far-end CSU
into loopback mode.
1. Rerun the test ds1-loop PCSS
far-csu-loopback-test-begin command.
2. If the test continues to fail, the problem could be with
the TN464F board, the CPE loopback jack
equipment, or somewhere between. Run the test
ds1-loop PCSS cpe-loopback-jack-test-begin
command to determine if the CPE loopback jack
loopback test is successful. If a CPE loopback jack
device is not being used, issue the test ds1-loop
PCSS ds1/csu-loopback-tests command instead.
If the closer loopback test fails, follow the
maintenance strategy that is associated with that
test; otherwise, escalate the problem.
3 FAIL The Far CSU Loopback Test was not set up properly.
The framed 3-in-24 test pattern, generated by the UDS1
Interface circuit pack and looped back through the
far-end CSU, could not be detected properly by the
UDS1 circuit pack.
1. Retry the
test ds1-loop PCSS
far-csu-loopback-test-begin
command.
2. If the Far CSU Loopback test continues to fail with
this error code, the problem could be with the
TN464F board, the far-end CSU equipment, or
somewhere in between. Run the
test ds1-loop
PCSS cpe-loopback-jack-test-begin
command to
see if the CPE Loopback Jack test which is closer to
the TN464F board is successful. (If a CPE Loopback
Jack device is not being used, then run the
test
ds1-loop PCSS ds1/csu-loopback-tests
command
to see if these even closer loopback tests succeed).
If the closer loopback test fails, follow the
maintenance strategy associated with that
loopback. Otherwise, escalate the problem.
Table 10-473. TEST #1213 Far CSU Loopback Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page