Routine Maintenance Procedures
Page 5-1Suppress Alarm Origination [y]
5
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
5
5
Routine Maintenance Procedures
The following general purpose maintenance procedures may be used with other
repair strategies to clear system-alarmed and user-reported troubles.
Suppress Alarm Origination [y]
When logged in as “craft”, no alarms are reported to INADS. After logging off,
INADS automatically reactivates, and any unresolved alarms are reported to
INADS.
Also, when logged in as “craft,” an automatic logoff of the terminal occurs after
30 minutes of non-use. At that time, any unresolved alarms are reported to
INADS. If you are logged in as “craft” at 2 different terminals, the logoff occurs
when the second terminal remains unused for 30 minutes.
NOTE:
The test inads-link command functions even if INADS Alarm Origination is
overridden.
Handling Control Circuit Packs
PPN Control Circuit Packs
!
WARNING:
It is NOT recommended that you reseat circuit packs unless the
documentation specifically instructs you to do so. If it is required to reseat a