Maintenance Object Repair Procedures
Page 10-878MET-LINE (MET Line)
10
In Service—Once the system receives a message from the voice terminal
communicating that it is present, the station is put into the in-service state.
The terminal can also be forced into the in-service state if it goes off-hook
while it is in the ready-for-service state.
When the status station command has been run, and the status screen
appears, the status is reported as either out-of-service, in-service (as stated in
the preceding list), or disconnect (the station is in the ready-for-service state).
Hardware Error Log Entries and Test to Clear
Values
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
2. Major or Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options command.
MET Line Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test port PCSSpp sh r 1
1 (a) 40987 None
18 (b) 0 busyout port
PCSSpp
WARNING OFF release port PCSSpp
130 (c) None WARNING ON test port PCSSpp sh
257 (d) 40988 None MIN/WRN
2
OFF
513 (e) 40965 Hybrid Line Station
Audits Test (#61)
WARNING OFF test port PCSSpp sh r 4
769 Port Diagnostic
Test (#35)
MIN/WRN
2
ON test port PCSSpp l r 3
1025 Hybrid & Conf.
Circuits Test (#57)
MIN/WRN
2
ON test port PCSSpp l r 3
1537 (f) 40968 None MIN/WRN
2
OFF
1793 TDMNPE Crosstalk
Test (#6)
MIN/WRN
2
ON test port PCSSpp l r 3
2049(g) 32770
2049(h) 40967
3840(i) 40989