DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-327CO-DS1 (DS1 CO Trunk)
10
0NO
BOARD
The test could not relate the internal ID to the port (no
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, an
insane board is inserted, or the board is hyperactive
(see Note below).
1. Check to ensure that the board translations are
correct. Use the list config command, and resolve
any problems that are found.
2. If the board was found to be correctly inserted in
step 1, issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should
re-establish the linkage between the internal ID and
the port. If this is not the case, dispatch to check to
ensure that there is a valid board inserted.
NOTE:
Hyperactivity causes some special problems with
the sequence suggested above. If the ports are
translated after issuing the list config command
but the ’Vintage’ field reports that there is no board
(when there really is a board), then the busyout
board and the release busy board commands
will not work (even though the reset board
command will work). The software will put the
hyperactive board back in service after the
hyperactivity clears.
Table 10-91. TEST #314 DS1CO Dial Tone Seizure Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page