DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-437DID-DS1 (DS1 DID Trunk)
10
1003 ABORT The system could not allocate a tone receiver for the test. The
system may be oversized for the number of tone detectors
present or some of the tone detectors may be out of service.
Issue the list measurements tone-receiver command to display
basic information about the system’s tone receivers.
1. Look for TTR-LEV errors in the error log. If present, refer to the
TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the error log. If present, refer to
the TONE-PT Maintenance documentation.
3. If neither condition exists, retry the test at 1 minute intervals
for a maximum of 5 times.
4. If the test continues to abort, escalate the problem.
1004 ABORT The port was seized by a user for a valid call. Use the display
port UUCSSpp command to determine the trunk group/member
number of the port. Issue the status trunk command to
determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for
certain tests. You must wait until the port is idle before retesting.
1. If the port status is idle, retry the command at 1 minute
intervals for a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1018 ABORT The test was disabled via translation. You may want to determine
why the test has been disabled before you enable it.
1. Verify that the ’Maintenance Test’ field on the ’Trunk
Administration’ screen is set to ’n’. To enable the test, change
the trunk administration and enter ’y’ into the ’Maintenance
Test’ field.
2. Repeat the test.
1020 ABORT The test did not run due to a previously existing error on the
specific port or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the
circuit pack and attempt to diagnose the previously existing
error.
Table 10-122. TEST #7 Conference Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page