DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-378DATA-BD (Network Control Circuit Pack)
10
Error Log Entries and Test to Clear Values
Notes:
a. This error indicates the DATA-BD portion of the Network Control circuit
pack stopped functioning. Since the Network Control circuit pack cannot
be reset via the reset board PCSS command, the Data Channel Reset
Test (#107) in the Long Test Sequence for the DATA-CHLs and
DATA-CON must be used to reset it as follows:
1. Issue the list data command to determine if one, or more, Network
Control Data Channels (DATA-CHLs) is administered.
NOTE:
A Network Control Data Channel (DATA-CHL) is identified by
a "type" value of "netcon."
2. If a Network Control Data Channel (DATA-CHL) is not administered,
use the add data-module [<ext> | next] command to administer a
DATA-CHL.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Table 10-103. Network Control Circuit Pack Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test data-module
<ext> sh r 1
1 (a) 0 Data Channel Reset
Test (#107)
MINOR ON test data-module
<ext> l
23 (b) 0 None WARNING OFF
257 Any Control Channel Test
(#52)
MINOR ON test network-control
[a | b] sh r 20
257 (c) 0 None
513 (d) Any None
769 (e) 4358 None
1025 (f) 4363 NPE Audit Test (#50) test network-control
[a | b] sh
1538 (g) Data Channel Reset
Test (#107)
MINOR ON test data-module
<ext> l
3840 (h) Any None
3841(i) Any None
3999(j) Any None