DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-954M/T-ANL (Maintenance/Test Analog Port)
10
1003 ABORT The system could not allocate a tone receiver for the
test. The system may be oversized for the number of
tone detectors present or some tone detectors may be
out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present,
refer to TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present,
refer to TONE-PT Maintenance documentation.
3. If neither condition exists, retry the test at 1 minute
intervals a maximum of 3 times.
4. If the test continues to abort, escalate the problem.
1004 ABORT The port has been seized by a valid ATMS test call.
1. Retry the command at 1 minute intervals a maximum
of 3 times.
2. If the test continues to abort and the port is not in
use on a valid ATMS Test Call, escalate the problem.
To determine whether the port is in use by an ATMS
Test Call enter status station ext where ext is the
assigned ATMS station number.
2000 ABORT Response to the test request was not received within the
allowable time period.
1. Retry the command at 1 minute intervals a maximum
of 3 times.
2. If the test continues to abort, escalate the problem.
2100 ABORT System resources required to run this test are not
available.
1. Retry the command at 1 minute intervals a maximum
of 3 times.
2. If the test continues to abort, escalate the problem.
Table 10-273. TEST #9 NPE Cross Talk Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page