Page 10-69ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line)
10
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to "TTR-LEV
(TTR Level)" Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to "TONE-PT
(Tone Generator)" Maintenance documentation.
3. If neither condition exists, retry the test at one-minute intervals a
maximum of five times.
1004 ABORT System resources required to run this test are not available. The port may
be busy with a valid call. Use the display port PCSSpp command to
determine the station extension. Use the status station command to
determine the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests. (Refer to the
"Status Commands" section in Chapter 8, "Maintenance Commands and
Trouble-Clearing Aids", for a full description of all possible states.) You
must wait until the port is idle before retesting.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort and the port is not in use, escalate the
problem.
1005 ABORT The test was aborted due to a configuration problem. This code will result
under either of the following conditions:
1. This test may not be applicable, or it may be disruptive to terminal
equipment other than a voice terminal (for example, the modem pool
member or music on hold).
2. The circuit pack is one of the following:
TN742 vintages 13,14 and 15
TN769 vintages 3,4 and 5
1018 ABORT Test disabled via administration. The default for the 'Test' field on the
'Station' form is 'y'; thus, you may want to determine why this field has
been set to 'n' on this station (this may be due to the ringing application
test 48, which can be customer or terminal disturbing).
1. To enable the test for a particular station, enter change station
extension and set the ‘Test?’ field on the ‘Station Form’ to ‘y.’
1020 ABORT The test did not run due to a previously existing error on the specific port
or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit
pack and attempt to diagnose the previously existing error.
Table 10-27. TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page