Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-902MET-LINE (MET Line)
10
1004 ABORT The port was seized by a valid call during the test. The
test has been aborted. Use the display port PCSSpp
command to determine the station extension, attendant
number, or trunk group/member number of the port. Use
the status station, status attendant, or status trunk
command to determine the service state of the port. If
the service state indicates that the port is in use, then
the port is unavailable for certain tests. (Refer to the
"Status Commands" section in Chapter 8, ‘‘
Maintenance
Commands and Trouble-Clearing Aids’’ for a full
description of all possible states.) You must wait until the
port is idle before retesting. Attendants are always in
use (off-hook) if the handset is plugged in and the port is
not busied out.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort and the port is not in
use, escalate the problem.
2000 ABORT Response to the test request was not received within the
allowable time period.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
FAIL The test failed due to an internal system error.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
Table 10-257. TEST #61 MET Line Station Audits Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page