DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-50change circuit-packs
8
Error Messages
If there is no "test hardware-group" command currently active to be canceled, the
following message will be displayed:
Command aborted - no hardware-group test in progress
If the command entered is in conflict with another currently executing command,
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
Output
If a "test hardware-group" command executing in the background is successfully
canceled with the "cancel hardware-group" command, the following response
will be displayed:
Hardware-group command successfully canceled
If a "test hardware-group" command executing in the foreground is successfully
canceled with a "cancel hardware-group" command from another SAT terminal,
the following response will be displayed on the SAT terminal where the
hardware-group command was executing:
Hardware-group command aborted with cancel command entered from another SAT
Feature Interactions
Scheduled and Periodic Maintenance
When a "test hardware-group" is entered, all activity related to scheduled
background maintenance, periodic background maintenance, and data audits is
suspended for the duration of the execution of the "test hardware-group"
command. All activity related to scheduled background maintenance, periodic
background maintenance, and data audits will restart if the "test hardware-group"
command is canceled.
Status Hardware-group
The state of a canceled "test hardware-group" command can be displayed by
means of the "status hardware-group" command and the state will show up as
’canceled’.
change circuit-packs
This command allows the user to add, change, or remove circuit packs which are
administered.