Maintenance Commands and Trouble-Clearing Aids
Page 8-423status conference
8
Drop Reason The reason for the channel’s disconnect:
2-pri This drop reason occurs when an administration error causes a
mismatch in primary-secondary designation for a cascade link. This
mismatch shows that both MCUs are administered as primaries (see
“Cascading” for a description of primary-secondary compatibility).
2-sec This drop reason occurs when an administration error causes a
mismatch in primary-secondary designation for a cascade link. This
mismatch shows that both MCUs are administered as secondaries (see
“Cascading” for a description of primary-secondary compatibility).
Agent The reservation agent has caused the call to disconnect (for
example, the agent has changed a connected dial-out destination
number).
Bandwidth mismatch between a call and the conference it attempted
to join. For example, a 56-kbps call attempted to join a 64-kbps
conference that does not allow rate adaptation.
BondHshake BONDing handshake drop reason can be caused due to
the following reasons: information channel parameter not supported or
invalid, parameter negotiation terminated out of sequence, timer
expired because of the secondary channels did not establish, or
BONDing framing was not detected for one of the other channels.
Busy This dial-out drop reason occurs when the MCU detects that the
conferee’s terminal equipment is busy. This drop reason is detected by
an ISDN cause value (for example h0). See “Dial-out” for a description
of CPTR usage.
Chair disconnected the endpoint, using either Chair Command
Disconnect (CCD) or Chair Command Kill (CCK) signals.
Conf End The conference was ended due to reaching stop time for a
reserved conference or due to an active conference being converted to
file.