DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-510status system
8
Synopsis
status system cabinet
Permissions
The following logins may execute this command: bcms, browse, system
technician, cust, inads, init, rcust.
Examples
status system 1st-cabinet
status system 2nd-cabinet
status system 3rd-cabinet
status system all-cabinets
Description
status system - This command displays the status, mode, and operational
attributes of the SPE(s), TDM and Packet busses, tone-clock circuit pack(s),
expansion interface links (exp-links), and emergency transfer switch of a single
cabinets or all cabinets in the system.
Defaults
No defaults.
Parameters
Help Messages
If the system technician presses HELP after entering "status system", the following
message will be displayed:
Please enter one of the following object command words:
1st-cabinet
2nd-cabinet
cabinet The cabinet specifies for which cabinet to display status. "1st-cabinet"
always refers to the PPN, "2nd-cabinet" refers to the 1st EPN, and
"3rd-cabinet" refers to the 2nd EPN. The status for one cabinet is
displayed on one page of output. If "all-cabinets" are specified, then
the user gets a 3 page output, one for each cabinet in the system. The
status displayed for a cabinet is always related to that cabinet except
in the case of status for EPNs and the SPE attributes. SPE attributes
always refer to PPN status regardless of which cabinet is being
displayed.