Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-546test analog-testcall
8
Description
The test analog-testcall command performs facility diagnostic tests on an entire
trunk group, an individual trunk group member, an individual trunk port or on all
trunks on a board, depending on the options entered by the technician. The type
of test call, the far end test line number and the various other test call related
parameters must be administered on the trunk group form before executing the
command. Press
HELP.
Normally the user should only invoke the full or supervision test. The other
options are provided primarily for testing when setting up an ATMS schedule.
Defaults
The default for the command is full with the repeat of 1.
Parameters
group number The group number is an administered number associated with each
trunk group.
member number The member number is an administered number identifying a
particular trunk within a trunk group. If a group number is entered,
and no member number is given, then all trunks in the group will be
tested.
location A "location" represents the physical position of the board or port to be
tested and is entered as "UUcSSpp" where "UU" represents the
cabinet number, "c" represents the carrier, "SS" represents the slot
position, and "pp" represents the circuit. A cabinet number (1 - 3)
may be entered. The "pp" should be omitted for a board location.
full This will execute the most comprehensive test call available using the
administered test set type.
supervision This will cause the system to execute a supervision only test call. It
will take about 10 seconds and will only confirm the presence of the
test set at the far end.
no-selftest This will execute the "full" test, but will skip any self test sequences.
This saves about 20 seconds on the type 105 transmission test and
will not have any effect on type 100 transmission tests or on type 102
transmission tests.
no-return-loss This will execute the "full" test, but will skip any return loss sequences.
This saves about 20 seconds on the type 105 transmission test and
will not have any effect on type 100 transmission tests or type 102
transmission tests.