Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1278STBY-SPE (Standby SPE)
10
This message line error, which corresponds to Error Codes 2012, 2013,
2014, 2015, 2021, 2024, 2048, 2049, 2050, or 2051, is displayed when a
refresh spe-standby command fails.
Standby SPE busy with another task; for information use status
system
This message line error, which corresponds to Error Code 2018, is
displayed if a test command on a Standby SPE component is attempted
while the Active SPE is performing some Maintenance Mode activity on
the Standby SPE other than system technician-demanded maintenance.
1. Issue the refresh spe-standby command to put the Standby SPE
into Standby Mode. This command may have to be issued multiple
times. If the refresh spe-standby command successfully
completes five times without the Standby SPE becoming labeled
"standby" on the status system form, wait 20 minutes. This does not
include cases where the command completes with the terminal
message line errors "Refresh not successful; use ‘display errors’ to
check for STBY-SPE errors" or "Cannot interrupt Standby SPE while
entering maintenance mode; please try later." Issue the refresh
spe-standby command once more. If the Standby SPE is not
labeled "standby" on the status system form after this attempt, use
the busyout spe-standby and release spe-standby command to
put the standby into standby mode.
2. Repeat the command.
3. Issue the test spe-standby long command.
Standby SPE failed to reset with requested restart level; check for
STBY-SPE errors
Standby SPE memory not refreshed; use the ‘refresh spe-standby’
command
When a command that requires the standby SPE to be brought into
maintenance mode is entered, but the standby SPE memory is not
refreshed, this message is displayed. Issue the refresh spe-standby
command and retry the command.
Standby SPE not available; for information use status system
This message line error, which corresponds to Error Code 2020, is
displayed if a test command on a Standby SPE component is attempted
within the first five minutes of a restart of the Active SPE (that is, prior to the
Active SPE holding the Standby SPE reset and refreshing it).
1. Issue the refresh spe-standby command to put the Standby SPE
into Standby Mode. This command may have to be issued multiple
times. If the refresh spe-standby command successfully
completes five times without the Standby SPE becoming labeled
"standby" on the status system form, wait 20 minutes. This does not
include cases where the command completes with the terminal
message line errors "Refresh not successful; use ‘display errors’ to