Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-366set tone-clock
8
If the cabinet entered is not within the valid range of cabinets or the cabinet is not
administered, the following message will be displayed:
Cabinet number not assigned
If there is no tone/clock board at the specified location, one of the following
messages will be displayed:
Board not inserted
Board not assigned
If the cabinet carrier location entered is that of an EPN that is not available, the
following message will be displayed:
EPN is not available
If the board is not a TN768 tone/clock board, the following message displays:
Cannot set tdm bus or tone/clock boards;
need a TN768 board
If the command entered is in conflict with another currently executing command,
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message will be displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, the following
message displays:
All maintenance resources busy; try again later
Output
If the tone/clock selected is out of service, the following message displays:
Tone/clock board is out-of-service;
use ’override’ option to force ’set’ command
The following message indicates that the command was unsuccessful, due to the
tone/clock being busied out:
Must release tone/clock board first
The following message indicates that the command was unsuccessful, due to the
epn in which the tone/clock resides not being available:
EPN is not available