Maintenance Commands and Trouble-Clearing Aids
Page 8-33busyout sp-link
8
Output
For the following output example, the command "busyout pri-endpoint 22501"
was entered. Assume that the PRI endpoint ports for extension 22501 are in
cabinet 1, carrier B, slot 20, circuit 1 to 6.
Feature Interactions
If there is an active call on the specified PRI endpoint, the busyout command will
cause the call to drop. This command is destructive.
Once the PRI endpoint is in the maintenance busy (system technician busy)
state, all call attempts from the far-end PRI terminal adapter will be denied with a
cause value 17 (User Busy).
busyout sp-link
This command will busyout the system printer link.
Port The port address (cabinet-carrier-slot-circuit) of the maintenance
object that is being busied out.
Maintenance Name The type of maintenance object that is being busied out. The
name for PRI endpoint port is "PE-BCHL."
Alt. Name The alternate way of identifying the maintenance object. This field
contains the extension number of the PRI endpoint.
Result An indicator as to whether the object is successfully busied out.
The possible values are: PASS, FAIL or ABORT.
Error Code A system-generated number that tells why the busyout failed or
aborted. A detailed list of the codes can be in the
"Busyout/Release Error Codes" section of this chapter.
busyout pri-endpoint 22501 SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01B2001 PE-BCHL 22501 PASS
01B2002 PE-BCHL 22501 PASS
01B2003 PE-BCHL 22501 PASS
01B2004 PE-BCHL 22501 PASS
01B2005 PE-BCHL 22501 PASS
01B2006 PE-BCHL 22501 PASS
Command Successfully Completed