DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-628test packet-control
8
For the following output example, assume that the entered command was "test
network-control a".
Feature Interactions
None.
test packet-control
This command will test the specified packet-control.
Synopsis
test packet-control
location [ short | long ][ repeat (1-100) | clear ] [ schedule ]
Test No The actual test that is being executed.
Result An indicator such as "PASS" for test passed, "FAIL" for test failed,
"ABORT" for test was aborted, "NO BOARD" for no Network
Control Board was inserted.
Error Code A system-generated number that tells why the individual test
failed or was aborted. A detailed list of the codes according to
"Test No." is provided for each maintenance object.
test network-control a
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01A DATA-BD 52 PASS
01AXX01 DATA-CHL 4001 109 PASS
01AXX01 DATA-CHL 4001 110 PASS
01AXX01 DATA-CHL 4001 111 PASS
01A SW-CTL 95 PASS
01A SW-CTL 92 PASS
01A SW-CTL 94 PASS
01A SW-CTL 324 PASS
01A 12V-PWR 701 PASS
01A CARD-MEM 695 PASS
01A CARD-MEM 696 PASS
01A CARD-MEM 697 PASS
01A CARD-MEM 698 PASS
01A CARD-MEM 699 PASS
Command Successfully Completed