DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-454DID-TRK (DID Trunk)
10
Table 10-125. TEST #33 Loop Around and Conference
Circuit Test
Error
Code
Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run
this test. This could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of
5 times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not
available. The port may be busy with a valid call. Use the
display port PCSSpp command to determine the station
extension, attendant number, or trunk group/member
number of the port. Use the status station, status
attendant, or status trunk command to determine the
service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain
tests. (Refer to the "Status Commands" section in Chapter
10, "Maintenance Commands and Trouble-Clearing Aids",
for a full description of all possible states.) You must wait
until the port is idle before retesting. Attendants are always
in use (off-hook) if the handset is plugged in and the port is
not busied out.
1. If the port status is active but the port is not in use (no
calls), check the Error Log for Error Type 513 (see Error
Log table for description of this error and required
actions). The port may be locked up.
2. If the port status is idle, then retry the command at
one-minute intervals a maximum of five times.
3. If the test continues to abort, escalate the problem.
Continued on next page