Maintenance Object Repair Procedures
Page 10-485DIG-LINE (Digital Line)
10
1003 ABORT The system could not allocate a tone receiver for the
test. The system may be oversized for the number of
Tone Detectors present or some Tone Detectors may be
out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present,
refer to TTR (TTR Level) Maintenance
documentation.
2. Look for TONE-PT errors in the Error Log. If present,
refer to TONE-PT (Tone Generator) Maintenance
documentation.
3. If neither condition exists, retry the command at
1-minute intervals a maximum of 5 times.
4. If the test continues to abort, escalate the problem.
1004 ABORT The port was seized by a valid call during the test. The
test has been aborted. Use display port UUCSSpp to
determine the station extension or attendant number of
the port. Use status station or status attendant to
determine the service state of the port. If the service
state indicates that the port is in use, then the port is
unavailable for certain tests. (See Chapter 10,
"Maintenance Commands and Trouble-Clearing Aids",
for a full description of all possible states.) You must wait
until the port is idle before retesting. Attendants are
always in use (off-hook) if the handset is plugged in and
the port is not busied out.
1020 ABORT Test disabled via background testing. Use status
station command to determine when station is available
for testing.
2000 ABORT Response to the test request was not received within the
allowable time period.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
Table 10-130. TEST #9 Digital Line NPE Crosstalk Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page