Page 10-683EXP-INTF (Expansion Interface Circuit Pack)
10
Table 10-195. TEST #242 Expansion Interface Lightwave
Transceiver Loop Around Test
Error
Code
Test
Result Description/Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system
may be under heavy traffic conditions or it may have time slots
out-of-service due to TDM-BUS errors. Refer to TDM-BUS (TDM
Bus) Maintenance documentation to diagnose any active
TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy
traffic, repeat test at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The
system may be oversized for the number of Tone Detectors present
or some Tone Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Hardware Error Log. If present,
refer to TTR-LEV (TTR Level) Maintenance documentation.
Even if there are no TTR-LEV errors, there still may not be a
Tone Detector available on the network that contains the circuit
pack being tested. Verify that there is at least one Tone
Detector on this network. If there is not at least one Tone
Detector, this test always aborts for this Expansion Interface
circuit pack. This does not harm the system in any way.
2. Look for TONE-PT errors in the Hardware Error Log. If present,
refer to TONE-PT (Tone Generator) Maintenance
documentation.
3. If neither condition exists, retry the test at 1-minute intervals a
maximum of 5 times.
1015 ABORT The system does not allow this test to be run because the
Expansion Interface circuit pack has not been busied out.
1. Busyout the Expansion Interface circuit pack. Repeat the test
board PCSS long command.
Continued on next page