41 FAIL The update files, translations, and announcements are different in
both SPEs. The Active SPE has the most current update file,
translations, and announcements.
42 FAIL The update files, translations, and announcements are different in
both SPEs. The Active SPE has the most current update file and
announcements, and the Standby SPE has the most current
translations.
1. Issue the save translations command.
2. Issue the save announcements command.
3. Have INADS issue the copy update-file command to copy the
update file from the Active to the Standby SPE.
4. Reissue the test card-mem long command to resolve the alarms.
44 FAIL The update files, load vintages, and announcements are different in
both SPEs. The Active SPE has the most current update file and
announcements.
45 FAIL The update files, load vintages, translations, and announcements are
different in both SPEs. The Active SPE has the most current update
file, translations, and announcements.
46 FAIL The update files, load vintages, translations, and announcements are
different in both SPEs. The Active SPE has the most current update
file and announcements, and the Standby SPE has the most current
translations.
1. Follow the procedures for Error Code 4 to get the correct load
vintage. Be sure to save the announcements. After running the
test card-mem long command, check for Error Codes 32 or 64.
Follow the recovery procedure under the applicable error code.
48 FAIL The update files and announcements are different in both SPEs. The
Active SPE has the most current update file, and the Standby SPE
has the most current announcements.
1. Follow the procedures for Error Code 40.
Table 10-205. TEST #421 Flash Data Consistency Check Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page