Page 10-721FL-DATA (Flash Data Consistency)
10
Notes:
a. See “CARD-MEM” for this test description.
b. See “12V-PWR” for a description of this test.
c. The Flash Data Consistency Test does not run in a Standard system.
Flash Data Consistency Check Test (#421)
The software vintage number, translation time stamps, announcement time
stamps, and update file time stamps and identifiers are read off of both memory
cards or SPEs and then compared. If the comparison shows any discrepancy,
FL-DATA is alarmed. This test is only run in a High or Critical Reliability system.
The test is run as part of the test card-mem long and as part of the standby PE
scheduled maintenance.
Table 10-205. TEST #421 Flash Data Consistency Check Test
Error
Code
Test
Result Description/Recommendation
0 ABORT The test timed out without completing. This error can occur when the
system is heavily loaded and the test is not allocated sufficient time to
run.
1. Rerun the test when the system is less busy and is not running
standby maintenance.
1029
1030
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2051
ABORT Refer to the STBY-SPE (Standby SPE) Maintenance documentation
for a description of these error codes.
Continued on next page