DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-424DC-POWER
10
c. Refer to “RING-GEN” for a description of this test.
NOTE:
Tests #117 and #118 only show up in the test sequence if there is a TN768
Tone-Clock circuit pack in the port network being tested.
Single-Carrier Cabinet Power Query Test (#79)
This test queries the Maintenance/Tape Processor (in a PPN) or the EPN
Maintenance circuit pack (in an EPN) about the status of the power in a
single-carrier cabinet system. This test can only detect power problems in
carriers in the Port Network for which the Carrier Port Power Unit is physically
present.
Table 10-120. TEST #79 Single-Carrier Cabinet Power Query Test
Error
Code
Test
Result Description/ Recommendation
1000 ABORT System resources required to run this test are not available.
1. Retry the command at 1minute intervals a maximum of 5 times.
2000 ABORT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1minute intervals a maximum of 5 times.
2. If the test continues to ABORT with Error Code 2000, check for system
powering problems with the A cabinet (PPN or EPN). Resolve all
DC-POWER alarms. Then, repeat the test. If the test continues to ABORT
with a 2000 Error Code, resolve all DUPINT (Duplication Interface Circuit
Pack) errors in a PPN for a high or critical reliability system, or MAINT
(EPN Maintenance circuit pack) errors in an EPN. Then, repeat the test.
2029 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page