DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1682XXX-BD (Common Port Circuit Pack)
10
1018 ABORT There are not any translated ports on the circuit pack, or
if there are ports, then none are administered to have
"neon."
1. Verify that there are ports administered on the circuit
pack. If no ports are administered, no further action
is required.
2. Make sure a TN755 or TN752 power unit circuit pack
is installed.
3. Verify that you have neon sets connected (AT&T sets
that may be neon sets are 500 and 2500 series, also
some non-AT&T may also be neon sets). If no neon
sets are connected to the circuit pack, the test
continues to abort, but no further action is required.
4. If there are no neon sets connected to the circuit
pack, at least one port needs to be translated with
neon. To check if a port is translated with neon, use
the display port PCSSpp command to determine
the station extension of any station on this circuit
pack. Use the display station <extension> to
determine if the port is administered with neon. The
field "Message Waiting Indicator:" must be set to
"neon" for at least one of the administered ports. If
this field is not administered to "neon" the test
continues to abort. This is acceptable because not
all stations have neon lamps on their analog
terminals. If none of the terminals have neon lamps,
the the test continues to abort, but no further action
is required.
Table 10-496. TEST #220 Neon Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page