DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-670test tdm
8
Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message will be displayed:
All maintenance resources busy; try again later
Output
The responses will be displayed on a test-by-test basis with one line of data
displayed for each test result.
The command that was entered was "test synchronization short".
Feature Interactions
None.
test tdm
This command tests all the time slots on a bus associated with a PPN or an EPN.
Port Not applicable.
Maintenance Name The maintenance object being tested is Synchronization.
Alt. Name Not applicable.
Test No. The actual test that is being executed.
Result The result of the individual test -"PASS," "ABORT," "FAIL," "NO
BOARD," "DISABLED," "EXTRA BD."
Error Code A system-generated number that tells why the release failed or
aborted. A detailed list of the codes according to "Test No." is
provided for each MO.
test synchronization short
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
SYNC 417 PASS
Command Successfully Completed