DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-604DTMR-PT [Dual Tone Multifrequency Port (TTR)]
10
Table 10-168. TEST #42 Tone Detection Verification Test
Error
Code
Test
Result Description/ Recommendation
none ABORT The system was not able to allocate all the resources
needed for this test or there was an Internal System
Error.
1 ABORT The system could not allocate all the resources needed
to test the DTMR port.
1001 ABORT The system was unable to put the DTMR port in the
appropriate mode to test it.
1002 ABORT The system could not allocate time slots for the test
connection. This could happen when the system is
heavily loaded. If the system is not heavily loaded, then
test the TDM Bus via the test tdm [a|b] command. Refer
to the TDM-BUS (TDM Bus) Maintenance
documentation for details.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1003 ABORT The system could not allocate a Tone Generator for the
test connection. This could happen when the system is
heavily loaded or there is not a Tone-Clock circuit pack
in the port network when this test is being executed.
1. Make sure there is a Tone-Clock circuit pack in the
same port network.
2. If a Tone-Clock circuit pack is missing, install one in
the same port network.
3. Allow about one-minute for the Tone-Clock
maintenance to run on the newly inserted
Tone-Clock circuit pack.
4. Retry the command at one-minute intervals a
maximum of five times.
5. If the test continues to abort, escalate the problem.
Continued on next page