DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-44busyout tone-clock
8
Parameters
Help Messages
If the system technician presses HELP after entering "busyout tone-clock," the
following message will be displayed:
Enter tone/clock location: [cabinet(1-3];(carrier(A-E))
Error Messages
If an identifier greater than 3 (three) characters is entered, or the cabinet entered
is not a digit (number), the following message will be displayed:
Identifier invalid
If the carrier entered is invalid, the following message will be displayed:
Invalid carrier specified
If the cabinet entered is not within the valid range of cabinets or the cabinet is not
administered, the following message will be displayed:
Cabinet number not assigned
If there is no tone/clock board at the specified location, one of the following
messages will be displayed:
Board not inserted
Board not assigned
If the specified cabinet carrier location is that of a switch node, the following
message will be displayed:
Switch Node carrier specified; invalid command for SN carrier
If the cabinet carrier location entered is that of an EPN that is not available, the
following message will be displayed:
EPN is not available
If the tone/clock is active and the specified action is busyout, the following
message will be displayed:
Illegal Command for active object; use ’set’ to switch to standby
If the command entered is in conflict with another currently executing command,
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
location A "location" represents the physical position of the tone/clock to be
busied out and is entered as "UUc" where "UU" represents the cabinet
number, and "c" represents the carrier. A cabinet number (1 - 3) may
be entered with or without a leading zero (0).