Maintenance Object Repair Procedures
Page 10-70ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line)
10
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required to run this test are not available. Either a
system allocation to get information about the port or to put the port into a
service state failed or the attempt to put the port in connection with a tone
source failed (this could be a tone-clock problem). The tone-clock and
tone detectors could be having a communication problem, for example,
the companding modes could be out of synchronization.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Table 10-27. TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page