Page 10-183BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port)
10
not indicate a problem with the ISDN-BRI circuit pack. This test is useful for
verifying the repair of the problem.
Table 10-60. TEST #624 Layer 1 Transmission Error Counter Test
Error
Code
Test
Result Description/ Recommendation
2000 ABORT Response to the test was not received from the circuit
pack within the allowable time period.
1. If the test aborts repeatedly a maximum of five
times, reset the circuit pack via the busyout board
PCSS and reset board PCSS commands.
2. If the test aborts again, replace the circuit pack.
2012 ABORT Internal System Error.
2100 ABORT Could not allocate necessary system resources to run
test.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to fail, escalate the problem.
value FAIL The BRI-LINE circuit pack is still detecting errors of this
type. The Error Code field contains the value of this
counter.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to fail, review the results of
other tests in the Long Test Sequence. Pay
particular attention to the results of the Level 1
Status Inquiry test. Follow repair procedures for any
of the executed tests if they fail. Otherwise, go to
the next step.
3. If the tests for the endpoints or adjunct pass and
the Layer 1 Transmission Error Counter Test
continues to fail, check the wiring to the endpoints
or adjunct. If the wiring appears to be fine, escalate
the problem.
PASS The Layer 1 Transmission error counter was read
correctly and has a value of 0.
Continued on next page