DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-203BRI-SET, ASAI-ADJ, BRI-DAT
10
2100 ABORT Could not allocate the necessary system resources to
run this test.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1113 FAIL The signaling link is not "bound" to the adjunct or
endpoint. For BRI endpoints supporting MIM
initialization, this error indicates that the endpoint has
not been bound to a signaling link (that is, SPID
initialization has not been completed). Since the
signaling link associated with the endpoint is not
identified until SPID initialization completes, this error
does not imply that the signaling link is connected or
disconnected at Layer 2 nor does it provide the status of
TEI assignment for the endpoint. For ASAI adjuncts and
BRI endpoints not supporting MIM initialization, this error
indicates that the link is disconnected at Layer 2. Since
the signaling link associated with the endpoint has been
identified via administration, the link is only "unbound"
from the endpoint when it is disconnected.
1. Execute the status bri-port PCSSpp command and
refer to the associated procedures for this command
contained in the BRI-PORT (ISDN-BRI Port)
Maintenance documentation.
2. If the test continues to fail, escalate the problem.
PASS The signaling link is connected at Layer 2 and "bound"
to the BRI endpoint or ASAI adjunct.
Table 10-66. TEST #626 Signaling Link Status Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page