DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-39ADX16A-PT (AUDIX Analog Line/Control Link)
10
f. The TDM bus is out of service. See the “TDM-BUS” section.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. By clearing
error codes associated with the
Loop Around Test #161
for example, you may
also clear errors generated from other tests in the testing sequence.
NO-OP Tests
The maintenance strategy for DEFINITY AUDIX emulates the one for ANL-16-L.
The tests listed below apply only to ANL-16-L and not to DEFINITY AUDIX. These
tests always return PASS.
■ Battery Feed Test (#35)
■ Audits and Updates Test (#36)
■ Station Present Test (#48)
Tests 36 and 48 ABORT when AUDIX is not running.
NPE Crosstalk Test (#6)
This test verifies that this port’s NPE channel talks on the selected time slot and
never crosses over to time slots reserved for other connections. If the NPE is not
working correctly, one-way and noisy connections may be observed. This test is
part of the long test sequence and takes about 25 seconds to complete.
1. D = Destructive; ND = Nondestructive
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
Loop Around Test (#161) X ND
Conference Test (#7) X ND
NPE Crosstalk Test (#6) X ND
Table 10-16. TEST #6 NPE Crosstalk Test
Error
Code
Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources for this test. Try (a).
Continued on next page