DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1489TONE-BD (Tone-Clock Circuit Pack)
10
Tone-Clock circuit pack will be in standby mode. Since the replacement
procedure was not successful, follow normal escalation procedures. If the
new Tone-Clock circuit pack is able to generate system clocks, there
will be no system disruption.
8. Place several phone calls.
9. After replacing a Tone-Clock circuit pack in an SPE, if the SPE lock
switches were set during the procedure, they should be released.
Additionally, after repairs in an EPN, the set tone-clock PC command
should be used if required to make the preferred Tone-Clock circuit pack
active.