DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-105ANN-BD (Announcement Circuit Pack)
10
FAIL Test failed. Announcements recorded or played back while the clock
circuitry is not functioning properly sound distorted. The ANN-BD may be
defective or the Active Tone-Clock circuit pack (TONE-BD) in the same
Port Network as the ANN-BD may be marginal and is causing this test to
fail.
1. Reset the circuit pack via the reset board PCSS command and then
run this test again. If the test continues to fail, proceed to Step 2 or 3
as applicable.
2. If this is a High or Critical Reliability system, determine the Active
TONE-BD in this Port Network via the status system command and
make the Standby Tone-Clock circuit pack active via the set
tone-clock PCSS command. Rerun the test. If the test passes, then
replace the now Standby Tone-Clock circuit pack. If the test continues
to fail, replace the ANN-BD circuit pack.
!
WARNING:
Replacing the circuit pack results in loss of integrated
announcements. See "General Notes" near the beginning of this
Maintenance procedure.
Table 10-38. TEST #212 Clock Match Inquiry Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page