DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1630UDS1-BD (UDS1 Interface Circuit Pack)
10
All trunks or ports on the UDS1 Interface circuit pack must be busied out via the
system technician busyout board command before running this End
Loopback/Span Test.
The
list measurements ds1 summary
command will display the length of time the
test ran (
Test Duration
field) and number of bit errors detected (
Loopback/Span
Test Bit-Error Count
field).
To restore the trunks or ports on the TN464F UDS1 Interface circuit pack to the
in-service state, execute the release board command
Table 10-476. TEST #1216 End Loopback/Span Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error
1. Retry the
test ds1-loop PCSS
end-loopback/span-test
command at 1-minute
intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1005 ABORT End Loopback/Span Test cannot be executed in the
current configuration. To run this, the TN464F or later
suffix UDS1 must be administered for 24-channel
operation. The "Bit Rate" field on the DS1 circuit pack
administration form must be set to "1.544" for 24-channel
operation.
1015 ABORT Ports on the UDS1 Interface circuit pack have not been
busied out to out-of-service.
1. Enter the busyout board PCSS command to put all
trunks or ports of the UDS1 Interface circuit pack
into the out-of-service state.
2. Retry the command.
3. If the test continues to abort, escalate the problem.
Continued on next page