DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1674XXX-BD (Common Port Circuit Pack)
10
Table 10-492. TEST #50 NPE Audit Test
Error
Code Test Result Description/ Recommendation
none or
2100
ABORT System resources required for this test are not
available.
1019 ABORT Test already in progress.
FAIL Internal System Error.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the
problem.
PASS The circuit pack’s NPEs have been updated with
their translation.
EXTRA BD Certain circuit packs have limitations on how
many circuit packs can be in the system or port
network such as the Maintenance/Test circuit
pack (TN771B or TN771C), the Tone Detector
circuit pack (TN748B, TN748C or TN748D) and
the Call Classifier (TN744). The Maintenance/Test
circuit pack allows only one circuit pack per port
network. The Tone Detector and Call Classifier
allow only 10 circuit packs in each system. All
additional circuit packs return EXTRA-BD and
should be removed.
any NO BOARD This is normal if the test is being done when (a)
the circuit pack is not physically in the system or
(b) the system is booting up. Otherwise, there is
some inconsistency between the physical
configuration and the data kept in the system.
1. Verify that the circuit pack is physically in the
system.
2. Verify that the system is not in a stage of
booting up.
3. Retry the command at one-minute intervals for
a maximum of five times.
4. If the test continues to return NO BOARD,
escalate the problem.
Continued on next page