Maintenance Object Repair Procedures
Page 10-1062PI-LINK (Processor Interface Link)
10
Processor Interface Loop Around Test (#182)
This test is destructive.
The Processor Interface Loop Around Test is an on-board Loop Around Test. The
test requires that the system technician issue a busyout link lnk-no command
before this test is run. This means that the DCS, AUDIX, or ISDN link, for
example, is torn down. It does not access the TDM Bus at all. When the circuit
pack is put into local loop around mode, frames are looped internally on the
circuit pack. If the test fails, the Processor Interface circuit pack reports the
failure. It is a good check of most of the working hardware on the Processor
Interface circuit pack.
1. D = Destructive; ND = Nondestructive
2. If the PI-LINK under test is BX.25 and if there is an MPDM or an MTDM as part of the link, then
the PI-LINK test sequence is expanded to include the tests on the data module. These tests are
run via the PDMODULE or TDMODULE maintenance object. Refer to the PDMODULE
TDMODULE (Data Module) Maintenance documentation for descriptions and details of these
tests.
Table 10-305. TEST #182 Processor Interface Loop Around Test
Error
Code
Test
Result Description/Recommendation
1 ABORT Link was not busied out via system technician.
1. Busyout the link via the busyout link lnk-no command.
2. Retry the test command.
2
4
9
ABORT 1. Retry the command at 1-minute intervals a maximum of 5 times.
16
80
84
85
93
94
102
ABORT Internal system error or possible TN765 PI-BD failure.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, then reset the PI-BD via the test interface
PCS long system technician command.
3. If problem still exists, replace the TN765 PI-BD.
Continued on next page