Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
About This Book
Page xviiGeneral
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
About This Book
General
This book has the information needed to monitor, test, and maintain DEFINITY
®
Enterprise Communications Server Release 5 Systems and covers many of the
faults and troubles that can occur in the system. Most maintenance requirements
are simple procedures due to the modular, self-testing nature of the system.
This document covers information related to DEFINITY ECS Release 5, and
includes all incremental releases up to and including Release 5.4. For details
about changes for Release 5.4, refer to
DEFINITY Enterprise Communications
Server Release 5.4.0, Change Description
, 555-230-471.
Simple, traditional troubleshooting methods are sometimes sufficient to locate
and clear faults. The traditional methods include terminal substitution, visual
inspections, continuity checks, and clarification of operating procedures with
users.
The information in this book is intended for use by:
A maintenance technician dispatched to a DEFINITY System site in
response to a trouble alarm or a user trouble report,
A maintenance technician located at a remote maintenance facility, or
The user’s assigned maintenance technician. The technician is expected
to have a knowledge of telecommunications fundamentals and of the
DEFINITY
Enterprise Communications Server Release 5 Systems to the
extent that the procedures in this book can be performed, in most cases,
without assistance.