Maintenance Object Repair Procedures
Page 10-1442TIE-DS1 (DS1 Tie Trunk)
10
reply and the timer expires, the test is aborted. Once the active message is
received, a dial pause message is sent to the DS1 Interface circuit pack. If the
DS1 Interface circuit pack replies with a dial pulse tone message when the far
end responds to the seizure, then the DS1 tie trunk Seizure Test passes. If the far
end does not respond to the seizure and the timer expires, and the DS1 Interface
circuit pack sends a reorder message back to the maintenance software, then
the test fails.
This second part of this test CANNOT be run on a trunk if one of the following
cases is true:
1. The trunk direction is administered as an incoming only trunk.
2. The trunk is the 24th port on a DS1 Interface circuit pack which is
administered using 24th Common Channel Signaling.
3. The trunk has been seized by a normal trunk call.
4. The trunk is administered with maintenance test disabled.
5. The outgoing signal type of the trunk is either automatic or
immediate-start.
Table 10-440. TEST #136 DS1 Tie Trunk Seizure Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error.
1000 ABORT System resources required to run this test were not
available. The port may be busy with a valid call. Use
the display port UUCSSpp command to determine the
trunk group/member number of the port. Use the status
trunk command to determine the service state of the
port. If the service state indicates that the port is in use,
then the port is unavailable for certain tests. You must
wait until the port is idle before retesting.
1. If the port status is active but the port is not in use
(no calls), check the error log for error type 1025
(see the error log table for a description of this error
and required actions). The port may be locked up.
2. If the port status is idle, retry the command at 1
minute intervals for a maximum of 5 times.
3. If the test continues to abort, escalate the problem.
Continued on next page