DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-27ADX8D-PT (AUDIX Digital Port)
10
7 FAIL Conference Test failed on the primary channel. Some users may not notice a
disruption in service. In extreme cases, the conferencing feature may not work
at all.
14 FAIL The primary voice channel is not transmitting properly. User impact may range
from no noticeable effect to loss of use of this port.
15 FAIL The control channel between the processor and DEFINITY AUDIX circuit pack
is not transmitting properly. User impact may range from no noticeable effect to
loss of use of this port. This failure could also be disruptive to other users.
16 FAIL The secondary voice channel is not transmitting properly. User impact may
range from no noticeable effect to loss of use of this port.
None FAIL The test failed for reasons external to the DEFINITY AUDIX circuit pack.
1. Run circuit pack tests to check the Tone Generator circuit pack and the
Tone Detector circuit pack by using the test board PCSS s command.
2. Resolve any problems that are detected on the Tone Generator circuit
pack or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit packs are functioning
properly, and if the test still fails, replace the AUDIX circuit pack (see
precaution at the beginning of this section).
PASS Voice and Control Channel Local Loop test passed. All channels are
transmitting properly.
1. To be sure that this is not an intermittent problem, repeat this test up to 10
times and see if it continues to pass.
2. If complaints still exist, examine the connections.
Table 10-11. TEST #13 Voice and Control Channel Local Loop Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page